Industrial gas detection and safety Inquiry: (8610) 13241121312 · james.liu@gzion.com

Canadian BW GP-QD Hydrogen Detector

Canada BW GP-QD Hydrogen Detector Relative Humidity: 5% to 95% RH (non-condensing) Sensor Service Life: Stainless steel encapsulated sensor…

Canadian BW GP-QD Hydrogen Detector
BW · Hydrogen Detector

Canadian BW GP-QD Hydrogen Detector

Canada BW GP-QD Hydrogen Detector Relative Humidity: 5% to 95% RH (non-condensing) Sensor Service Life: Stainless steel encapsulated sensor…

BrandBW
CategoryHydrogen Detector

Product details

Relative humidity: 5% to 95% RH (non-condensing) Sensor lifespan: Stainless steel packaged sensor, full lifespan above warranty period: one year

Product Details

Feature

▲ All sensors are plug-in and replaceable: electrochemical, catalytic combustion
   IR (Infrared Sensor)
▲ Automatic monitoring of the sensor's working status and end-of-life reminder
▲ Simple calibration and automatic zeroing and automatic verification programs, background light
   Automatic backlight in low light and alarm conditions
▲ Three 5amP relay outputs, low and high alarms, and failure alarm, with optional off/on function
▲ Two LCDOs digitally display gas concentration and sensor status indicators
▲ There is an intuitive panel button when needing to set an alarm point
▲ Programmable alarms as needed, comprehensive instrument failure self-diagnosis function
▲ Line Digital Information Exchange Extended MODBUS

 Technical specifications

Monitor:  3-wire 4-20mA output, advanced microprocessor control
Operating power: 12 to 32 VDC DC power supply
Current output:
Normal operation: 4-20mA
Calibration mode: Stable 3mA (automatically resets to normal operation)
Failure mode: 2mA (or smaller)
Power consumption
PoisonousGas: 40mA at 24 VDC
Catalytic gas: 100mA at 24 VDC
Relay Gas: 50mA at 24 VDC
Sensors:  Insertion sensor, stainless steel packaging
Test Type: Combustible gas: Catalytic combustion sensor
             IR infrared sensor
      PoisonousQi and harmonyOxygenElectrochemical Sensor
Automatic Testing: Automatic real-time testing of sensor integrity
      Service life of sensors
Relative Humidity: 5% to 95% RH (non-condensing)
  • Standard: No professional training required, achieved through buttons, automatic
  • Zeroing and calibration.
  • Display:Two LCDs operate the chess module separately, quickly
  • LCD1: 3-digit number real-time display of gas readings
  • LCD2: Real-time display of operational status in alphanumeric text
  • Alarm Settings: Set two alarm points, which the user can choose to set
  • Relay Output: Three SPDT relays, 5 amp at 250 VAC
  • Low/High: Select normal voltage and switch on site
  • Failure: normal voltage and not turned off
  • Dimensions and weight: 17 × 17.8 × 10.8 cm / 2.2 kg
  • Monitoring instrument: Protection class NEMA4, explosion-proof type, enclosure anodized
  • Handle with installation flange
  • Sensor lifespan: Stainless steel packaged sensor, usage
  • All of the lifespan
  • Warranty period: one year

Specifications and dimensions

Poisonous/OxygenSensors

Combustible gasSensors

22AMG

0.64mm

2045 meters

1022 meters

20AMG

0.75mm

3,253 meters

1626 meters

18AMG

1.0mm

5167 meters

2583 meters


Order Model

Gas

Detection accuracy

Resolution

Temperature range

unit

Measurement range

GP-WD

LEL

1%

1

40 to 90°C

%

 0-100

GP-IR-WD

LEL

1%

1

40 to 70°C

%

 0-100

GP-HD

H2S

0.25ppm

1

40 to 50°C

ppm

 0-20,0-50,0-100,0-500

GP-MD

CO

1ppm

1

20 to 50℃

ppm

 0-50,0-100,0-500,0-1000

GP-AD

NH3

1ppm

1

10 to 50℃

ppm

 0-200,0-50,0-500,0-1000

GP-ZD

HCN

0.1ppm

0.1

20 to 50℃

ppm

 0-20.0,0-5.00,0-100

GP-DD

NO2

0.1ppm

0.1

20 to 50℃

ppm

 0-50.0,0-10.0,0-20.0,0-99,9

GP-SD

SO2

1ppm

1

20 to 50℃

ppm

 0-100,0-50.0-20,0-10

GP-XD

O2

0.1%

0.1

20 to 50℃

%

 0-30.0

GP-CD

CI2

0.1ppm

0.1

20 to 50℃

ppm

 0-5.0,0-10.0,0-100.0

How to order

For model selection, calibration accessories or bulk quotes, call (8610) 13241121312 or use the inquiry form.