Industrial gas detection and safety Inquiry: (8610) 13241121312 · james.liu@gzion.com

Hydrogen detector OLCT100 Oldham France

Audim France OLCT100 Hydrogen Detector ■ Detects explosive gases, toxic gases, and oxygen ■ Infrared XP IR version ■ Delivers exceptional p…

Hydrogen detector OLCT100 Oldham France
Other brands · Hydrogen Detector

Hydrogen detector OLCT100 Oldham France

Audim France OLCT100 Hydrogen Detector ■ Detects explosive gases, toxic gases, and oxygen ■ Infrared XP IR version ■ Delivers exceptional p…

BrandOther brands
CategoryHydrogen Detector

Product details

■ Detects explosive gases, toxic gases, and oxygen
■ Infrared XP IR version
■ Delivers exceptional value
■ SIL 2 High reliability

OLCT100Technical specifications

Model

OLC100

OLCT100 XP LEL

OLCT100 XP IR

OLCT100 XP EC

OLCT100 XP HT

OLCT100 XP SC

OLCT100 IS

Materials

Epoxy-coated aluminum casing. 316 stainless steel casing is available

Sensors

Catalytic combustion

Catalytic combustion

Infrared

Electrochemistry

Catalytic combustion

Semiconductors

Electrochemistry

Size (mm)

138×133

×84

138×133

×84

138×133

×84

138×133

×84

138×133

×84

138×133

×84

138×133

×84

Weight (kg)

0.950

1

1.1

1.1

1.8

1.1

1.1

Protection rating

IP66

Electrical interfaces

M20 or 3/4 NPT

Power supply voltage

Provided exclusively by the Incisco Oldam controller

15.5 V ~ 32 V

13.5 V ~ 32 V

10 V ~ 32 V

15.5 V ~ 32 V

15.5 V ~ 32 V

15.5 V ~ 32 V

Average power consumption

340 mA

110 mA

60 mA

23.5 mA

100 mA

100 mA

23.5 mA

Relative humidity (non-condensing)

0 ~ 95 % RH

0 ~ 95 % RH

0 ~ 95 % RH

It depends on the type of sensor

0 ~ 95 % RH

20 ~ 95 % RH

It depends on the type of sensor

Pressure

Atmospheric ± 10%

Response time

  • T50 = 6 seconds
  • T90 = 15 seconds
  • Against methane
  • T50 = 6 seconds
  • T90 = 15 seconds
  • Against methane

CO2 version

  • T50 = 10 seconds
  • T90 = 15 seconds
  • LEL Version:
  • T50 = 10 seconds
  • T90 = 15 seconds

It depends on the type of sensor

  • T50 = 6 seconds
  • T90 = 15 seconds
  • Against methane

It depends on the type of sensor

It depends on the type of sensor

Average life expectancy

36~48 months

36~48 months

> 48 months

It depends on the type of sensor

36~48 months

36~48 months

It depends on the type of sensor

Temperature range

40°C ~ +70°C

40°C ~ +70°C

25°C ~ +55°C

It depends on the type of sensor

20°C ~ +200°C

20°C ~ +60°C

It depends on the type of sensor

Storage temperature

50 ~ 70°C

50 ~ 70°C

4 ~ 20°C

It depends on the type of sensor

50 ~ 70°C

20 ~ 50°C

It depends on the type of sensor

Storage humidity

20 ~ 60 % RH

20 ~ 60 % RH

20 ~ 60 % RH

It depends on the type of sensor

20 ~ 60 % RH

20 ~ 60 % RH

It depends on the type of sensor

Stored air pressure

1 bar ± 10 %

1 bar ± 10 %

1 bar ± 10 %

It depends on the type of sensor

1 bar ± 10 %

1 bar ± 10 %

It depends on the type of sensor

Storage time

Up to 6 months

Up to 6 months

Up to 6 months

It depends on the type of sensor

Up to 6 months

<, /TD>

Up to 6 months

It depends on the type of sensor

Output signal

  • Current: 0 ~ 23 mA (unisolated)
  • 4 - 20mA linear output (within range)
  • 0 mA: circuit failure or no power supply
  • < 1mA: Fault
  • 2 mA: Initialization mode
  • > 23 mA: Out of range

Certification

Complies with the European Explosion-Proof Directive ATEX 94/9/CE and IECEx related provisions regarding explosion-proof detectors. Obtained SIL 2 certification according to EN 50402 / EN 61508,

The metrology performance standards comply with EN 50054 and EN 50057 (harmonized standards 61779-1:2000 and 61779-4:2000), and electromagnetic compatibility complies with EN 50270

Cables

3-core shielded cable

3-core shielded cable

3-core shielded cable

2-core shielded cable

3-core shielded cable

3-core shielded cable

2-core shielded cable

How to order

For model selection, calibration accessories or bulk quotes, call (8610) 13241121312 or use the inquiry form.

Related products