Product details
|
■ Detects explosive gases, toxic gases, and oxygen OLCT100Technical specifications
Model OLC100 OLCT100 XP LEL OLCT100 XP IR OLCT100 XP EC OLCT100 XP HT OLCT100 XP SC OLCT100 IS Materials Epoxy-coated aluminum casing. 316 stainless steel casing is available Sensors Catalytic combustion Catalytic combustion Infrared Electrochemistry Catalytic combustion Semiconductors Electrochemistry Size (mm) 138×133 ×84 138×133 ×84 138×133 ×84 138×133 ×84 138×133 ×84 138×133 ×84 138×133 ×84 Weight (kg) 0.950 1 1.1 1.1 1.8 1.1 1.1 Protection rating IP66 Electrical interfaces M20 or 3/4 NPT Power supply voltage Provided exclusively by the Incisco Oldam controller 15.5 V ~ 32 V 13.5 V ~ 32 V 10 V ~ 32 V 15.5 V ~ 32 V 15.5 V ~ 32 V 15.5 V ~ 32 V Average power consumption 340 mA 110 mA 60 mA 23.5 mA 100 mA 100 mA 23.5 mA Relative humidity (non-condensing) 0 ~ 95 % RH 0 ~ 95 % RH 0 ~ 95 % RH It depends on the type of sensor 0 ~ 95 % RH 20 ~ 95 % RH It depends on the type of sensor Pressure Atmospheric ± 10% Response time CO2 version It depends on the type of sensor It depends on the type of sensor It depends on the type of sensor Average life expectancy 36~48 months 36~48 months > 48 months It depends on the type of sensor 36~48 months 36~48 months It depends on the type of sensor Temperature range 40°C ~ +70°C 40°C ~ +70°C 25°C ~ +55°C It depends on the type of sensor 20°C ~ +200°C 20°C ~ +60°C It depends on the type of sensor Storage temperature 50 ~ 70°C 50 ~ 70°C 4 ~ 20°C It depends on the type of sensor 50 ~ 70°C 20 ~ 50°C It depends on the type of sensor Storage humidity 20 ~ 60 % RH 20 ~ 60 % RH 20 ~ 60 % RH It depends on the type of sensor 20 ~ 60 % RH 20 ~ 60 % RH It depends on the type of sensor Stored air pressure 1 bar ± 10 % 1 bar ± 10 % 1 bar ± 10 % It depends on the type of sensor 1 bar ± 10 % 1 bar ± 10 % It depends on the type of sensor Storage time Up to 6 months Up to 6 months Up to 6 months It depends on the type of sensor Up to 6 months Up to 6 months It depends on the type of sensor Output signal Certification Complies with the European Explosion-Proof Directive ATEX 94/9/CE and IECEx related provisions regarding explosion-proof detectors. Obtained SIL 2 certification according to EN 50402 / EN 61508, The metrology performance standards comply with EN 50054 and EN 50057 (harmonized standards 61779-1:2000 and 61779-4:2000), and electromagnetic compatibility complies with EN 50270 Cables 3-core shielded cable 3-core shielded cable 3-core shielded cable 2-core shielded cable 3-core shielded cable 3-core shielded cable 2-core shielded cable |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||