Product details
- Explosion-proof certificate number
- IECEx SIR 08.0009X, Code Ex d IIC
- SIRA 08ATEX1031X, Code Ex d IIC
- Temperature code
- T4 (Ta -20 to +60°C)
- T5 (Ta -20 to +50°C)
- T6 (Ta -20 to +35°C)
- Standard
- IEC 60079-0:2004 (Edition 4)
- IEC 60079-1:2007-04 (Edition 6)
- EN60079-0:2006
- EN60079-1:2007
- Probe technical specifications
- Material: Housing: Aluminum alloy casting; Sensor: 316 stainless steel
- Electrical interface 3/4" NPT
- Weight: 1.0 Kg (excluding protective cover)
- Range: O2 0-25
- Input voltage: 24 V DC
- Maximum input power is 5W
- Internal insurance 1A
- Analog output is 4-20mA
- Electrochemical principles of sensors
- Reaction time depends on the detected gas sensor
- Resolution 0.05%
- Protection rating IP66
- Calibration is completed using a dedicated regulator, or zero points and sensitivity are calibrated using buttons inside the probe
- Operating temperature from -40 to +65°C
- Humidity range: 0-95% RH, no condensation
- Working Pressure Atmospheric Pressure ±10%
- Performance standards EN 61779-1:2000, EN 61779-4:2000, EN 61779-5:2000
- Material: Housing: aluminum alloy, sensor: stainless steel 316, magnetic adjustment pen: stainless steel 316
- Weight: 1.75kg
- Detection gases and range: O2: 0-25% VOL CO: 0-1000 ppm
- H2S: 0-100ppm NH3: 0-100ppm
- Relay: Dry contact 3A, 300V AC
- Output: 4-20mA, RS232
- Electrochemical principles of sensors
- Protection rating: IP68 (sensor IP65)
- Explosion-proof rating: EEx d IIC T6
- Displays 4-bit LCD