American Incisco OLCT10 nitrogen dioxide detector

American Insco OLCT10 Nitrogen Dioxide Detector Detection Gas: Nitrogen Dioxide Range: 0-30ppm Detector OLC 10 / OLC 10 TWIN OLCT 10 Detect…

American Incisco OLCT10 nitrogen dioxide detector
Other brands · Carbon dioxide detector

American Incisco OLCT10 nitrogen dioxide detector

American Insco OLCT10 Nitrogen Dioxide Detector Detection Gas: Nitrogen Dioxide Range: 0-30ppm Detector OLC 10 / OLC 10 TWIN OLCT 10 Detect…

BrandOther brands
CategoryCarbon dioxide detector

Product details

  • American Incisco OLCT10 nitrogen dioxide detector
  • Detected gas: nitrogen dioxide
  • Installation method: Wall-mounted
  • Connect cable 3-wire connector M20 (outer diameter 5.5~12mm), 1-wire connector M16 (outer diameter dimensions).
  • 4~8mm)
  • Protection IP31
  • Power supply: 230 or 115 VAC; 21~30 VDC VDC (generally 24 VDC)
  • Power is 20 VA
  • Temperature range -10~45°C
  • Sensor cables can be installed with single or dual OLCT10 probes for boiler rooms, LPG detection, and detection of methane, butane, and propane
  • It can be used to detect vehicles and parking lots' natural gas, hydrogen, and other gases.
  • One OLCT10 detection transmitter can be installed for boiler rooms, LPG detection of methane, butane, and propane, and can also be installed
  • Used to detect natural gas, hydrogen, and other gases in vehicles and parking lots.
  • Can be equipped with 1-5 OLCT10 probes for parking lot measurements CO.NO.NO.2.
  • Terminal 1: Signal output / 2: 0V / 3: 24 VDC
  • Maximum transmission distance OLC10 (gas only): 3-wire system, shielded cable, core wire specification 1~1.5mm², maximum transmission
  • 300 meters away
  • Dual OLC10 (gas only): 4-wire system, shielded cable, core wire specification 1~1.5mm², maximum transmission
  • Transmission distance: 300 meters.
  • OLCT10 (Combustible Gas): 3-wire shielded cable, core wire specification 1~1.5mm², maximum transmission distance
  • 1 km away.
  • OLCT10 (Toxic Gas): 2-wire system, shielded cable, core wire specification 0.75~1.5mm², maximum transmission
  • Distance is 4 kilometers.
  • LCD screen display, 4-digit numeric display
  • Status indicator lights: 4 indicator lights displayed. Green: Power supply, Red: Alarm, Orange: Malfunction
  • Gases and units can be selected via the controller
  • The panel has three buttons for maintenance, testing, and confirmation: 1: Enter/Menu, 2: -/Test Instructions, 3: /Confirm
  • Alarm and Relay: Two independently programmable relays can be set. The alarm status can be set to latch or not, and alarm points can be set
  • Placement. Remote or local alarm confirmation.
  • The relay status can be set to normally open or normally closed.
  • A default fault alarm relay
  • Relay capacity: 2A, 250 VAC
  • 2A,30VDC
  • Certified 3G Certification (EN61779-1 and EN61779-4)
  • EN61010
  • EN50270

How to order

For model selection, calibration accessories or bulk quotes, call (8610) 13241121312 or use the inquiry form.